Liftsplus.com

375-1042

Skip to product information

375-1042

24VDC Contactor Panel Mount Single-Pole

Regular price $94.24
Sale price $94.24 Regular price $76.85
In stock

Questions? Call +1-800-669-7554

Contactor Contactors Electric Lift Truck Parts

Compatibility

Make -
Model -

Reference Diagrams

Visit our diagram page for part references to popular models


Product Description

Contactor, OEM part number 375-1042 for electric lift trucks. 24VDC coil voltage, panel mount configuration, molded insulated frame, single-pole normally open contactor suitable for battery-powered material handling equipment.

Specifications

Electrical Specifications
Coil Voltage24VDC
Control Voltage24VDC nominal
Material & Construction
Frame MaterialMolded glass-filled polyester cover, plated steel hardware
Mechanical Specifications
Terminal Type3/8 inch UNC stud terminals for power connections; #10 screw or faston terminals for coil connection
Dielectric Strength1500V RMS minimum between open contacts and coil
Part Numbers & Compatibility
OEM Part Number375-1042
Performance Specifications
Mechanical Life250,000 operations minimum at full rated current

Frequently Asked Questions

Q: What applications is the 375-1042 contactor designed for?
A: The 375-1042 is a single-pole normally open contactor designed for battery-powered electric lift trucks and material handling equipment. The 24VDC coil voltage and panel mount configuration make it suitable for OEM control circuits in electric pallet jacks, reach trucks, and similar equipment.

Q: What are the key electrical specifications of the 375-1042?
A: The 375-1042 has a 24VDC coil voltage and 24VDC nominal control voltage. It features 1500V RMS minimum dielectric strength between open contacts and the coil. The molded glass-filled insulated frame provides structural integrity and electrical isolation in industrial environments.

Q: What terminal types does this contactor use?
A: The 375-1042 uses two terminal styles. Power connections connect via 3/8 inch UNC stud terminals, while the coil connection uses either #10 screw terminals or faston terminals, depending on your control circuit design.

Q: How does the molded insulated frame benefit this contactors performance?
A: The molded glass-filled frame provides electrical isolation, reduces arcing, and protects internal contacts from contamination. This design extends service life in material handling environments where dust, moisture, and vibration are common.

Q: What dielectric strength does the 375-1042 provide?
A: The 375-1042 is rated for 1500V RMS minimum dielectric strength between open contacts and the coil. This rating ensures safe isolation between high-voltage power circuits and low-voltage control circuits in 24VDC systems.