Product Description
Crown OEM Fuse CR 076924-6 is a 175-amp, 130VDC time-delay class ACK fuse specifically engineered for Crown PE 3000 series electric pallet trucks, cross-referenced to multiple OEM numbers for Hyster, Caterpillar, Yale, Clark, and others. Key attributes include heavy-duty current interruption, bolt-on terminal mounting, and construction for high-cycle battery and traction protection.
Specifications
Electrical
| Fuse Rating | 175 A |
| Voltage Rating | 130 VDC max |
Part Numbers
| OEM Part Number | CR 076924-6 |
| Alternate Part Number | 076924-006 |
| Cross-Reference Part Numbers | 0840387 [Hyster], 0973793 [Caterpillar], 195334 [Hyster], 220006358 [Yale], 220016839 [Yale], 220028997 [Yale], 220101050 [Yale], 3054294 [Hyster], 3136997 [Hyster], 343101 [Hyster], 350983 [Hyster], 352-1145 [LPM], 42069 [E-Parts], 445864 [Clark], 6252915 [Hyster], 800108973 [TVH], 840387 [Hyster], 906237 [Namco], 973793 [Caterpillar], ACK-175 [Drexel], ACK175 [Linde], P170-0175 [Dockstocker], SYBUACK175 [TVH], SYBU-ACK175 [TVH], SYBU-ACK-175 [TVH], SYBU-ECK175 [TVH], SYBU-ECK-175 [TVH] |
| Compatible Equipment Models | Crown PE 3000 series pallet trucks |
Performance Specifications
| Peak Arc Voltage | 130 VDC (maximum circuit voltage limit) |
Frequently Asked Questions
Q: What are the electrical specifications for the CR 076924-6?
A: The CR 076924-6 is a 175-amp, 130VDC time-delay class ACK fuse engineered for Crown PE 3000 series electric pallet trucks. It provides high-cycle battery and traction protection through heavy-duty current interruption capability.
Q: What equipment is the CR 076924-6 compatible with?
A: The CR 076924-6 fits Crown PE 3000 series electric pallet trucks and cross-references to multiple OEM part numbers: Hyster 0840387, 195334, 3054294, 3136997, 343101, 350983, 352-1; Caterpillar 0973793; Yale 220006358, 220016839, 220028997, 220101050. Verify part compatibility with your specific model.
Q: What is the mounting style for the CR 076924-6?
A: The CR 076924-6 uses bolt-on terminal mounting, allowing secure, repeatable connection to the lift truck electrical system. Bolt-on terminals provide reliable contact and are standard for high-current material handling equipment.
Q: How does the time-delay rating affect the CR 076924-6 performance?
A: Time-delay classification means the fuse tolerates brief current surges during motor startup without nuisance blowing. This protects battery and traction circuits while still safeguarding equipment if sustained overcurrent occurs. Class ACK fuses are specifically rated for battery-powered material handling applications.
Q: What happens if I use a non-time-delay fuse instead of the CR 076924-6?
A: A non-time-delay fuse would blow during normal motor startup surges, causing repeated fuse replacement and downtime. The CR 076924-6 time-delay design prevents this nuisance blowing while maintaining overcurrent protection for battery and traction motor circuits.
Q: How long does the CR 076924-6 typically last in service?
A: A properly functioning CR 076924-6 provides years of service under normal operating conditions. Fuse replacement is needed only when system overcurrent events occur. Frequent replacement may indicate charger, battery, or motor problems requiring diagnosis.