Product Description
SAS-5403 Solenoid, 24VDC continuous-duty relay for electric lift truck control applications. Compatible with Prestolite and PLSAS-5403A cross references. High-impact phenolic construction, 5/16"-24 terminals
Specifications
Dimensional
| Mounting Hole Pattern | 1.75 inch center-to-center |
Electrical
| Coil Voltage | 24VDC continuous duty |
| Current Rating | 12A nominal at 24VDC |
Material & Construction
| Enclosure Material | High-impact phenolic resin body |
Part Numbers
| Cross-Reference Part Numbers | Prestolite SAS-5403A; PLSAS-5403A |
| Manufacturer Part Number | SAS-5403 |
| Equivalent Part Numbers | SAS-5403A; PLSAS-5403A-1-ORG |
Performance
| Max Inrush Current | 60A at 24VDC |
| Contact Rating | Continuous 12A at 24VDC |
Frequently Asked Questions
Q: What are the electrical specifications for the SAS-5403 solenoid relay?
A: The SAS-5403 is rated 24VDC continuous duty with a nominal current rating of 12A at 24VDC. It is a continuous-duty relay designed for electric lift truck control applications where lower current switching is required.
Q: What material is the SAS-5403 enclosure made from?
A: The SAS-5403 has a high-impact phenolic resin body construction. This material provides impact resistance and insulation suitable for electric material handling equipment, though it is not metal like some other solenoid models.
Q: What terminal size does the SAS-5403 use?
A: The SAS-5403 features 5/16 inch-24 terminals for electrical connections. Verify terminal size compatibility with your equipment wiring and connection posts before ordering.
Q: What are the equivalent part numbers for the SAS-5403?
A: The SAS-5403 is equivalent to Prestolite SAS-5403A, PLSAS-5403A, and PLSAS-5403A-1-ORG. Cross-check your equipment documentation to confirm the correct solenoid model before ordering.
Q: How does the SAS-5403 differ from the higher-amperage SAS-5403A model?
A: The SAS-5403 is rated 12A continuous duty and uses a phenolic resin body. The SAS-5403A is rated 100A continuous duty with a metal case and is designed for heavier load applications. Select the correct model based on your equipments current requirements and control circuit design.